Signs

Where braille goes on a sign, and where the sign goes

Below the text and 3/8 inch clear of anything raised; the tactile characters 48 to 60 inches above the floor, beside the door on its latch side.

A sign made to every dimension in Table 703.3.1 still fails if it is mounted on the wrong side of the door, and a reader who cannot find a sign is no better off than one who cannot read it. Placement is half the standard.

Where the braille sits on the sign (703.3.2)
RuleClauseNote
Braille shall be positioned below the corresponding text, and below all of it where the text runs to more than one line703.3.2On elevator car controls the braille may sit directly below the raised characters or beside them.
Braille shall be separated 3/8 inch (9.5 mm) minimum from any other tactile characters and from raised borders and decorative elements703.3.2On elevator car controls the separation drops to 3/16 inch (4.8 mm).
Where the sign sits in the building (703.4)
RuleClauseNote
Tactile characters shall be 48 inches (1220 mm) minimum above the floor, measured from the baseline of the lowest character, and 60 inches (1525 mm) maximum, measured from the baseline of the highest703.4.1Two different measurements, taken from two different characters. A tall sign can put its lowest line under 48 inches while its highest is still under 60, and fail on the first. Elevator car controls are excepted.
At a door, the sign goes alongside it on the latch side703.4.2On the wall, not on the door. Where there is no wall space at the latch side, the sign goes on the nearest adjacent wall.
At double doors with one active leaf the sign goes on the inactive leaf; with two active leaves it goes to the right of the right-hand door703.4.2With one active leaf the sign is on a door, the inactive one. Where there is no wall space to the right of double doors, it goes on the nearest adjacent wall.
A clear floor space of 18 by 18 inches (455 by 455 mm) minimum, centred on the tactile characters, beyond the arc of any door swing between closed and 45 degrees703.4.2Signs are permitted on the push side of a door that has a closer and no hold-open device.

Signs put up under the 1991 Standards

Before the 2010 Standards, placement was one clause of the 1991 ADA Standards, 4.30.6, and its height rule measures something else: “60 in (1525 mm) above the finish floor to the centerline of the sign”. 703.4.1 measures from the tactile characters, not from the sign, and its 60 inches is a maximum.

Placement in the 1991 Standards (4.30.6) and the 2010 Standards (703.4)
What1991, 4.30.62010, 703.4
Height60 inches (1525 mm) above the floor to the centerline of the signThe baseline of the lowest tactile character 48 inches (1220 mm) minimum, of the highest 60 inches (1525 mm) maximum
A single doorOn the wall adjacent to the latch side; with no wall space there, the nearest adjacent wallAlongside the door at the latch side; with no wall space there, the nearest adjacent wall
Double doorsThe nearest adjacent wallThe inactive leaf where one leaf is active; to the right of the right-hand door where both are
In front of the signA person may approach within 3 inches (76 mm) without meeting a protruding object or standing within the swing of a door18 by 18 inches (455 by 455 mm) of clear floor, centred on the tactile characters, beyond the arc of the door swing from closed to 45 degrees

Hung to the 1991 rule, a sign has its centre at 60 inches, so any tactile character whose baseline is above that centre is above the 2010 maximum.

Which of the two a building follows is a matter of dates. For a business, the Department of Justice takes the date of the last application for a building permit, or the start of construction where no permit is needed; for a state or local government building, the start of construction. Where that date is on or after 15 March 2012, new construction and alterations must comply with the 2010 Standards.

Questions and answers

How high should a braille sign be mounted?

Tactile characters sit at least 48 inches (1220 mm) above the floor measured from the baseline of the lowest character, and no more than 60 inches (1525 mm) measured from the baseline of the highest (703.4.1). Elevator car controls are excepted.

Which side of the door does a braille sign go on?

Alongside the door on the latch side, not on the door itself. At double doors with one active leaf the sign goes on the inactive leaf (703.4.2).

Where these figures come from

Every dimension and rule on this page is from the 2010 ADA Standards for Accessible Design, and the earlier rule from the 1991 ADA Standards for Accessible Design (4.30.6), both published by the United States Department of Justice and checked against their own text, as are the compliance dates. These are the federal 2010 ADA Standards. A given project may also be under a state or local code with its own requirements, California's Title 24 among them. Check the standard itself before specifying a sign; every clause quoted here is linked to its source.